MODEL I-125
KWIK-LATCH® CURRENT PROBE
The PRODYN KWIK-LATCH® Current Probes are wide band
devices designed to mea-sure current on cable bundles and other RF
sources without having to disconnect the conductor. The probes
have a mid-sized aperture of 1.25 inches and have a hinged two
piece design that is durable and easy to use. The I-125 Current
Probes have a 50 W output load impedance and come with a type 'N'
connector standard.
(Other connector types are available at a slight additional charge.)

|
MODEL
|
Zt W
|
USABLE FREQUENCY RANGE
|
3 db POINTS
|
| |
|
|
|
| I-125-1A |
5
|
10 KHz to 100 MHz
|
110 KHz to 90 MHz
|
| I-125-1D |
5
|
1 KHz to 110 MHz
|
25 KHz to 80 MHz
|
|
I-125-1E
|
5 |
850 Hz to 120 MHz |
5 KHz to 70 MHz |
| I-125-1 HF |
5
|
50 KHz to > 1 GHz
|
120 KHz to>600 MHz
|
| I-125-2A |
1
|
10 KHz to 150 MHz
|
30 KHz to 80 MHz
|
| I-125-2C |
1
|
300 Hz to 25 MHz
|
600 Hz to 10 MHz
|
| I-125-2 HF |
1
|
50 KHz to > 1 GHz
|
80 KHz to >500MHz
|
| I-125-7A |
1
|
400 Hz to 100 MHz
|
540 Hz to 30 MHz
|
| I-125-6A |
.5
|
20 Hz to 30 MHz
|
60 Hz to 10 MHz
|
| I-125-4A |
.1
|
1 KHz to 150 MHz
|
4 KHz to 110 MHz
|
| I-125-3A |
.03
|
1 KHz to 250 MHz
|
10 KHz to 180 MHz
|
| I-125-9A |
.005
|
1 KHz to 270 MHz
|
10 KHz to 200 MHz
|
| |
|
|
|
Additional electrical data available upon request.
PRODYN manufactures current probes with larger or smaller apertures and different
frequency ranges. Please ask for additional information.